Occup Environ Med

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cherniack, M
Right arrow Articles by Fu, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cherniack, M
Right arrow Articles by Fu, R
Occupational and Environmental Medicine 2003;60:962-968
© 2003 BMJ Publishing Group Ltd


ORIGINAL ARTICLE

Skin temperature recovery from cold provocation in workers exposed to vibration: a longitudinal study

M Cherniack, A Brammer, J Meyer, T Morse, D Peterson, R Fu

University of Connecticut Health Center, Farmington, CT, USA

Correspondence to:
Correspondence to:
Dr M Cherniack
Ergonomics Technology Center, University of Connecticut Health Center, 263 Farmington Avenue-MC6210, Farmington, CT 06030-6210, USA; cherniack{at}nso.uchc.edu

Background: Vibration white finger (VWF) is characterised by arterial hyperresponsiveness and vasoconstriction following cold provocation. Several years after of removal from exposure, most subjects show improved finger systolic blood pressure (FSBP) under conditions of cold challenge, but continue to report cold hands and finger blanching.

Aims: To assess the underlying reasons for the persistence of cold symptoms.

Methods: A total of 204 former users of pneumatic tools with cold related hand symptoms were evaluated and then re-evaluated a year later. Symptoms were evaluated using the Stockholm Workshop Scale. Finger systolic blood pressure per cent (FSBP%) was assessed by comparing digital blood pressure in a cold provoked and normalised state. Fingertip skin temperature was measured during cooling and occlusion and during rewarming and recovery.

Results: There were dramatic improvements in FSBP% (14.3 mm Hg %), modest improvement in recovered skin temperature (0.86°C), and no change in symptom stage. When the most symptomatic subjects (n = 75) were compared with the less symptomatic subjects (n = 129), there were similar inter-test improvements in FSBP%. Skin temperature recovery improved in the less symptomatic (+1.49°C), but did not change in the most symptomatic group (-0.12°C). However, the more symptomatic group had higher temperatures at the initial test, thus qualifying the result.

Conclusions: Skin temperature recovery after cold challenge in subjects with VWF remains reduced in the symptomatic subjects several years after exposure removal. This is evident even when blood pressure has increased in the setting of cold provocation. Results suggest that in VWF, the dermal circulation remains impaired, even after the restoration of arterial blood pressure in the digits.


Keywords: hand arm vibration syndrome; finger systolic blood pressure; cold challenge plethysmography; Raynaud’s phenomenon; vasospasm

Abbreviations: FSBP, finger systolic blood pressure; FST, finger skin temperature; FTI, finger temperature index; HAVS, hand-arm vibration syndrome; RWI, rewarming index; VWF, vibration white finger







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 by the BMJ Publishing Group Ltd.